Shcherbina et al., 2017
Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort
- PMID
- 28538708
- PMCID
- PMC5491979
- DOI
- 10.3390/jpm7020003
THE BIOHACKING REFERENCE
Compare study populations, methods, findings and limitations, or place editorial topics side by side.
Wrist-worn heart rate versus ECG, in three historical adult cohorts.
Look at who was studied, how readings were collected and what each result can support. These studies use different cohorts, devices and sampling procedures; no pooled estimate or present-day device ranking is offered.
Showing all three studies. Selection and export controls become available when JavaScript loads.
Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort
Accuracy of commercially available heart rate monitors in athletes: a prospective study
Accuracy of wearable heart rate monitors in cardiac rehabilitation
60 healthy adults; convenience recruitment with diversity selection.
50 healthy athletic adults, age 18–56; 68% male, 76% White.
80 adults in cardiac rehabilitation; mean age 62, 19% female.
Participant; 80 tests are not 80 independent people.
Participant; 25 participants per wrist model.
Participant; repeated time points are not additional patients.
Laboratory criterion validation; two device batches; fixed activity sequence.
Prospective laboratory validation; randomized device and wrist assignment.
Prospective criterion validation; randomized wrist-device allocation.
Concurrent 12-lead ECG, Quark CPET.
Three-lead ECG, Quinton Q-tel RMS; trained visual reading.
Torso limb-lead ECG, Quinton Q-tel RMS; cardiologist-supervised visual reading.
Walking, running, cycling; final minute per stage, device-specific extraction.
Six treadmill speeds, readings after two minutes; handrail gripping during roughly five-second observation.
Individually prescribed treadmill/cycle exercise; readings at 3, 5, 7 minutes.
Relative error; repeated-measures modeling; selected Results only.
Concordance, paired differences, Bland–Altman; mixed model for repeated observations.
ECG-minus-device differences, absolute differences, concordance, Bland–Altman.
Selected Results report less heart-rate error during cycling than walking in this protocol.
Authors report declining wrist-device agreement at faster treadmill speeds.
Fitbit treadmill mean signed difference was 0.5 bpm but mean absolute difference 8.2 bpm (Table 2); near-zero bias can coexist with individual error.
No accuracy percentages reproduced: walking threshold text is internally inconsistent; supplements and broader notice reconciliation remain pending.
Rendered concordance decimals are malformed; exact coefficients and device ranking withheld pending figure/publisher reconciliation.
Descriptive paired readings, not an exercise prescription or participant-level confidence interval.
Retained Methods 151–228 and selected Results 229–247; native current PMC challenge and PubMed footer.
Main Methods/statistics 135–197, Results 199–216 and limitations 223–225 read.
Main Methods 175–204, Results 206–317, limitations 335–338 read.
Exact DOI search found publisher notes; notes request returned 429. No notice clearance.
PubMed identity matched; exact DOI notice search found no identity-matched notice. Bounded screen only.
Identified erratum read: corrects coauthor name to Zade Akras; no numerical change in that notice.
No registry body inspected.
NCT03612063 reported by paper; direct registry returned shell, so prespecification unverified.
NCT03182439 reported by paper; registry shell prevents prespecification check.
Manufacturer instructions; no independently verified calibration or firmware versions.
Placement described; proprietary algorithms and firmware not verified.
Electrode preparation and wrist placement described; firmware/calibration not independently verified.
Convenience selection; excluded malfunctioning device; device-specific acquisition; missing-data exclusion in PCA.
Selected fit volunteers; altered arm motion; visual timing; missingness/registry agreement not established.
Visual timing; model-specific missing displays; selected single-center cohort; limited subgroup precision.
Concerns and unresolved checks; no low-bias designation.
Concerns and unresolved checks; no low-bias designation.
Concerns and unresolved checks; no low-bias designation.
As recorded in the complete synthesis: Three included primary studies, one retained and two newly read; source details are not claims about present-day devices.
The comparison retains original study-record text. These file hashes identify the complete canonical artifacts, not a new appraisal or a hash of only the selected rows. Raw publisher bodies remain outside this site’s repository.
c5216f51890b07c41af5663942a5c941db888fa0004ce49194bb4dca3ce8842d845bba5c4201644be9e3a7bff69d07e04631be41a44e2d27428d2c29570d79508b20c1ac234a13e8c91a76e9317b28049412367e733c75e9352ee5cdb141638ff1c19b16e5c243d6cbb6a499193fa0c639debbe105af84247d028050b8f3a617fe7c6fad05b1c640c40187c0cbc96666fa2ba6e76b69955d45834802d36114d85b10ab96f50c09295ab94168602cf001aca3af4d740f2ae2e2e92f40789fd8f284538aa2868110f3ab7ad8e50bfcd389d3b266d6562c321c437b1be275e1b157Put two topics side by side to inspect scope, evidence grade, risk, source coverage, clinical framing, and protocol guardrails. This is an orientation tool, not a recommendation engine.