Three historical primary studies in adults during aerobic exercise.
The question is how closely optical wrist readings agree with concurrent ECG during aerobic exercise. The evidence supports protocol-specific conclusions; no pooled accuracy estimate is justified here.
What the evidence supports
Agreement depends on the tested activity and sampling procedure; there is no single transferable accuracy number for a wrist device.
Heterogeneous cohorts and historical models; no pooled estimate or causal comparison of populations.
Two newly inspected Methods sections and one hash-reconciled retained Methods section. “Inspected” records access and assessment, not low risk of bias.
Selected Results report less heart-rate error during cycling than walking in this protocol.
Limit: No accuracy percentages reproduced: walking threshold text is internally inconsistent; supplements and broader notice reconciliation remain pending.
Methods, source access and unresolved checks
Design
Laboratory criterion validation; two device batches; fixed activity sequence.
Independent unit
Participant; 80 tests are not 80 independent people.
Tested models
Apple Watch (generation unspecified); Basis Peak v1; Fitbit Surge; Microsoft Band v1; Mio Alpha 2; PulseOn; Samsung Gear S2
Sampling
Walking, running, cycling; final minute per stage, device-specific extraction.
The protocol was frozen before retrieval on 7 November 2026. Eligible publication dates were 1 January 2010 through 7 November 2026. Seven targeted web-search operations returned 75 result blocks, including duplicates and irrelevant records; this was not a complete PubMed database search. Six primary candidates were attempted, and three were included.
Ten of 22 open operations returned challenges, rate limits, footers or registry shells. A newer 2025 candidate could not be assessed beyond its abstract and early text. Another candidate remains held because its minimum participant age was unspecified and its error table requires reconciliation. These gaps limit currency and coverage.
The identified Etiwy erratum was read and corrects a coauthor name. Shcherbina’s publisher notes were inaccessible; broader notice assessment remains unresolved. No inaccessible correction is treated as harmless, and no comprehensive absence-of-notices claim is made.
Raw native responses remain outside Git. A repository clone supplies authored notes, source links and hashes, not publisher article bodies or the machine-specific evidence archive.
Continue the review
Resolve source-text inconsistencies, registry records, missingness and firmware details before extending quantitative claims. Retrieve the blocked recent Methods through supported public tools or lawfully supplied text. A qualified external reviewer should assess extraction, agreement statistics, selection bias and clinical applicability.